Advertisement
Letter to the Editors-in-Chief| Volume 164, P45-47, April 2018

Download started.

Ok

Continuous exploration of parameters derived from multiple electrode platelet aggregometry is warranted

Published:February 17, 2018DOI:https://doi.org/10.1016/j.thromres.2018.02.138
      Platelet function evaluated by multiple electrode aggregometry (MEA) (Multiplate® analyzer, Roche, Basel, Switzerland) is increasingly explored in various settings [
      • Ivert T.
      • Dalen M.
      • Ander C.
      • Stalesen R.
      • Nasman P.
      • Lordkipanidze M.
      • et al.
      Platelet function one and three months after coronary bypass surgery in relation to once or twice daily dosing of acetylsalicylic acid.
      ,
      • Hetherington J.J.
      • Ford I.
      • Ashcroft G.P.
      • Jansen J.O.
      Intraoperative changes in platelet function in relation to moderate haemorrhage.
      ,
      • Morel-Kopp M.C.
      • Mullier F.
      • Gkalea V.
      • Bakchoul T.
      • Minet V.
      • Elalamy I.
      • et al.
      Heparin-induced multi-electrode aggregometry method for heparin-induced thrombocytopenia testing: communication from the SSC of the ISTH.
      ]. Among others, personalization of acetylsalicylic acid treatment [
      • Ivert T.
      • Dalen M.
      • Ander C.
      • Stalesen R.
      • Nasman P.
      • Lordkipanidze M.
      • et al.
      Platelet function one and three months after coronary bypass surgery in relation to once or twice daily dosing of acetylsalicylic acid.
      ], platelet function in response to a surgical stimuli [
      • Hetherington J.J.
      • Ford I.
      • Ashcroft G.P.
      • Jansen J.O.
      Intraoperative changes in platelet function in relation to moderate haemorrhage.
      ] and testing for heparin-induced thrombocytopenia [
      • Morel-Kopp M.C.
      • Mullier F.
      • Gkalea V.
      • Bakchoul T.
      • Minet V.
      • Elalamy I.
      • et al.
      Heparin-induced multi-electrode aggregometry method for heparin-induced thrombocytopenia testing: communication from the SSC of the ISTH.
      ] are relevant clinical applications for MEA. A previously published study by our group provided the reference intervals of platelet aggregation in hirudin whole blood [
      • Rubak P.
      • Villadsen K.
      • Hvas A.M.
      Reference intervals for platelet aggregation assessed by multiple electrode platelet aggregometry.
      ]. The study only focused on the parameter area under the aggregation curve (AUC), measured in arbitrary aggregations units (AU) *minutes (min). However, other parameters of the Multiplate® analyzer are readily available, in particular the maximum aggregation amplitude (measured in AU) as well as the slope of the aggregation curve designated aggregation velocity (AU/min). The AUC is suggested as the main parameter by the manufacturer [
      • Toth O.
      • Calatzis A.
      • Penz S.
      • Losonczy H.
      • Siess W.
      Multiple electrode aggregometry: a new device to measure platelet aggregation in whole blood.
      ,
      • Siller-Matula J.M.
      • Christ G.
      • Lang I.M.
      • Delle-Karth G.
      • Huber K.
      • Jilma B.
      Multiple electrode aggregometry predicts stent thrombosis better than the vasodilator-stimulated phosphoprotein phosphorylation assay.
      ]. It is empirically sound to suggest the AUC as the main parameter owing to its composite nature including aspects of aggregation velocity as well as aggregation amplitude. Accordingly, the AUC is often highlighted as the optimal parameter [
      • Toth O.
      • Calatzis A.
      • Penz S.
      • Losonczy H.
      • Siess W.
      Multiple electrode aggregometry: a new device to measure platelet aggregation in whole blood.
      ], although no data have been presented demonstrating the superiority of the AUC. Furthermore, the manufacturer also introduced the AUC in units (U) where 1 U corresponds to 10 AU ∗ min [
      • Siller-Matula J.M.
      • Christ G.
      • Lang I.M.
      • Delle-Karth G.
      • Huber K.
      • Jilma B.
      Multiple electrode aggregometry predicts stent thrombosis better than the vasodilator-stimulated phosphoprotein phosphorylation assay.
      ]. Subsequently, there has been some confusion in the literature regarding the use of U, which is sometimes referred to as AU [
      • Sorigue M.
      • Morales-Indiano C.
      • Ruiz-Garcia L.
      • Pena M.
      • Nieto J.
      • Martinez-Iribarren A.
      • et al.
      Adoption of bio/data collagen for the assessment of platelet function with the multiplate(R) analyzer.
      ], even though the term AU should be restricted to the parameter maximum amplitude and not the AUC. In any case, when data exploration is restricted to the AUC, potential information available in the basic parameters maximum amplitude and velocity may be neglected.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Thrombosis Research
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Ivert T.
        • Dalen M.
        • Ander C.
        • Stalesen R.
        • Nasman P.
        • Lordkipanidze M.
        • et al.
        Platelet function one and three months after coronary bypass surgery in relation to once or twice daily dosing of acetylsalicylic acid.
        Thromb. Res. 2017; 149: 64-69
        • Hetherington J.J.
        • Ford I.
        • Ashcroft G.P.
        • Jansen J.O.
        Intraoperative changes in platelet function in relation to moderate haemorrhage.
        Thromb. Res. 2015; 135: 1198-1202
        • Morel-Kopp M.C.
        • Mullier F.
        • Gkalea V.
        • Bakchoul T.
        • Minet V.
        • Elalamy I.
        • et al.
        Heparin-induced multi-electrode aggregometry method for heparin-induced thrombocytopenia testing: communication from the SSC of the ISTH.
        J. Thromb. Haemost. 2016; 14: 2548-2552
        • Rubak P.
        • Villadsen K.
        • Hvas A.M.
        Reference intervals for platelet aggregation assessed by multiple electrode platelet aggregometry.
        Thromb. Res. 2012; 130: 420-423
        • Toth O.
        • Calatzis A.
        • Penz S.
        • Losonczy H.
        • Siess W.
        Multiple electrode aggregometry: a new device to measure platelet aggregation in whole blood.
        Thromb. Haemost. 2006; 96: 781-788
        • Siller-Matula J.M.
        • Christ G.
        • Lang I.M.
        • Delle-Karth G.
        • Huber K.
        • Jilma B.
        Multiple electrode aggregometry predicts stent thrombosis better than the vasodilator-stimulated phosphoprotein phosphorylation assay.
        J. Thromb. Haemost. 2010; 8: 351-359
        • Sorigue M.
        • Morales-Indiano C.
        • Ruiz-Garcia L.
        • Pena M.
        • Nieto J.
        • Martinez-Iribarren A.
        • et al.
        Adoption of bio/data collagen for the assessment of platelet function with the multiplate(R) analyzer.
        Thromb. Res. 2017; 161: 33-35
        • Kaiser A.F.
        • Neubauer H.
        • Franken C.C.
        • Kruger J.C.
        • Mugge A.
        • Meves S.H.
        Which is the best anticoagulant for whole blood aggregometry platelet function testing? Comparison of six anticoagulants and diverse storage conditions.
        Platelets. 2012; 23: 359-367
        • Andreasen J.B.
        • Pistor-Riebold T.U.
        • Knudsen I.H.
        • Ravn H.B.
        • Hvas A.M.
        Evaluation of different sized blood sampling tubes for thromboelastometry, platelet function, and platelet count.
        Clin. Chem. Lab. Med. 2014; 52: 701-706
        • Pedersen O.H.
        • Nissen P.H.
        • Hvas A.M.
        Platelet function investigation by flow cytometry: sample volume, needle size, and reference intervals.
        Platelets. 2017; : 1-4
        • Jeppesen A.N.
        • Kirkegaard H.
        • Ilkjaer S.
        • Hvas A.M.
        Influence of temperature on thromboelastometry and platelet aggregation in cardiac arrest patients undergoing targeted temperature management.
        Crit. Care. 2016; 20: 118