Effect of prothrombin time outlier exclusion rules on ISI calibration in multicentre studies

  • A.M.H.P. van den Besselaar

      Affiliations

    • Department of Thrombosis and Hemostasis, Leiden University Medical Center, Leiden, The Netherlands
    • Corresponding Author InformationCorresponding author. Department of Thrombosis and Hemostasis, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands. Tel.: +31 71 5261894; fax: +31 71 5266755.
  • ,
  • V. Chantarangkul

      Affiliations

    • Angelo Bianchi Bonomi Hemophilia and Thrombosis Center, Department of Internal Medicine, University and Foundation IRCCS Ospedale Maggiore Policlinico, Mangiagalli and Regina Elena, Milan, Italy
  • ,
  • A. Tripodi

      Affiliations

    • Angelo Bianchi Bonomi Hemophilia and Thrombosis Center, Department of Internal Medicine, University and Foundation IRCCS Ospedale Maggiore Policlinico, Mangiagalli and Regina Elena, Milan, Italy

Received 19 August 2009; received in revised form 11 December 2009; accepted 11 January 2010. published online 22 February 2010.

Abstract 

International Sensitivity Index (ISI) calibration is based on prothrombin time (PT) determinations in fresh plasma samples of healthy (normal) individuals and patients treated with vitamin K-antagonists (VKA). The ISI is calculated from the slope of the orthogonal regression line of the log(PT) results. The ISI calibration model is based on the assumption that the mean logarithms of the PT's of the normals are found on the orthogonal regression line derived using patients’ samples. According to World Health Organization (WHO) guidelines, patients’ samples with International Normalized Ratio (INR) beyond the 1.5 to 4.5 interval shall be excluded for ISI calibration. According to the WHO guidelines, outlier samples are defined as those at a perpendicular distance from the orthogonal regression line greater than 3 residual standard deviations, and shall be excluded as well. The purpose of the present study was to assess the effect of sample exclusion on ISI calibration, using the data base of three historic multicenter studies performed in 1990, 1995 and 2005, respectively. Various rules for sample exclusion were tried. In comparison to calibration without any exclusion, between-laboratory variation of the ISI was slightly reduced by sample exclusion using the WHO rule. Furthermore, the adequacy of the ISI calibration model was improved. The effect of the WHO sample exclusion rule on the mean value of the ISI of the current International Standards for thromboplastins was not greater than approximately 1%. It is concluded that the WHO rule for sample exclusion is appropriate for reliable ISI calibration.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0049-3848(10)00013-7

doi:10.1016/j.thromres.2010.01.006

Thrombosis Research
Volume 125, Issue 6 , Pages 523-528, June 2010